{
    "act_title": "Jharkhand Building Byelaws 2016",
    "act_slug": "jharkhand-building-byelaws-2016",
    "section_label": "Section",
    "section": {
        "number": "82",
        "title": "82. E-Governance.",
        "chapter": null,
        "content": "Chapter - XI\nAffordable Housing\n83. \"Affordable Housing Project\".\n83.7 Means of access\nLength of road limitation\nLength of road limitation\nSl.\nSl.\nMaximum Length of the road in Meter\nMaximum Length of the road in Meter\nMinimum width of road of street in Meter\n\t\t\t\t(Inclusive of passive Development)\nMinimum width of road of street in Meter\n\t\t\t\t(Inclusive of passive Development)\n(i)\n(i)\n(ii)\n(ii)\n(iii)\n(iii)\n1\nUpto 100 m\n3.6 meter 5.1\n2\nExceeding 100 meter and upto 300 meter\n4.5 meter 6.6\n3\nExceeding 300\n6.6 meter 7.5\n83.8 Minimum setbacks and height of residential buildings\nSl.\nSl.\nAverage Depth of plot (In meters)\nAverage Depth of plot (In meters)\nBuilding height Upto G+2 Maximum-10m\nBuilding height Upto G+2 Maximum-10m\nBuilding Height Upto G+3 Maximum-12m\nBuilding Height Upto G+3 Maximum-12m\nBuilding Height Upto G+4 Maximum-15m\nBuilding Height Upto G+4 Maximum-15m\nMinimum Front set back (m)\nMinimum Front set back (m)\nMinimum Rear set back (m)\nMinimum Rear set back (m)\nMinimum Front set back (m)\nMinimum Front set back (m)\nMinimum Rear set back(m)\nMinimum Rear set back(m)\nMinimum Front Rear set back(m)\nMinimum Front Rear set back(m)\nMinimum set back (m)\nMinimum set back (m)\n(i)\n(i)\n(ii)\n(ii)\n(iii)\n(iii)\n(iv)\n(iv)\n(v)\n(v)\n(vi)\n(vi)\n(vii)\n(vii)\n(viii)\n(viii)\n1\nExceeding 15m & upto 33m\n3.0\n1.8\n3.0\n2.0\n3.0\n2.0\n2\nExceeding 33m & upto 45 m\n4.0\n3.0\n4.5\n3.0\n4.5\n3.5\n3\nMore the 45m\n4.0\n3.0\n4.0\n4.0\n5.0\n5.0\n83.9 Minimum side setbacks for residential buildings\nSl.\nSl.\nAverage Width of plot (In meters)\nAverage Width of plot (In meters)\nBuilding Height Upto G+2 Maximum-10m\nBuilding Height Upto G+2 Maximum-10m\nBuilding Height Upto G+3 Maximum-12m\nBuilding Height Upto G+3 Maximum-12m\nBuilding Height Upto G4-4 Maximum-15 m\nBuilding Height Upto G4-4 Maximum-15 m\n(i)\n(i)\n(ii)\n(ii)\n(iii)\n(iii)\n(iv)\n(iv)\n(v)\n(v)\n(vi)\n(vi)\n(vii)\n(vii)\n(viii)\n(viii)\n3\nExceeding 15m & upto 27m\n1.5\n1.5\n1.5\n1.5\n2.0\n2.0\n5\nExceeding 27m & upto 39m\n2.0\n2.0\n2.5\n2.5\n3.0\n3.0\n7\nExceeding 39m & upto 45m\n3.0\n3.0\n3.60\n3.60\n4.50\n4.50\n8\nMore the 45m\n3.60\n3.60\n4.00\n4.00\n5.00\n5.00\n83.10 Minimum exterior open spaces around the buildings for all type of high rise buildings unless otherwise specified\nSl.\nSl.\nHeight of the Building Upto (m)\nHeight of the Building Upto (m)\nExterior open spaces to be left out on all\n\t\t\t\tsides in m.\nExterior open spaces to be left out on all\n\t\t\t\tsides in m.\n(front setback)\n(front setback)\nSide and back\nSide and back\n1\nMore than 15 and upto 18\n6.5\n4.5\n2\nMore than 18 and upto 21\n7.0\n4.5\n3\nMore than 21\n7.5\n4.5\nEWS: car parking for 50% of the units, balance 2 wheeler parking\nLIG & MIG: car parking for 100% of the units\n86.15.1 EWS               -               Carpet Area- 30sqm.\n86.15.2 LIG                 -               Carpet Area- 60sqm.\nEWS\nEWS\nLIG\nLIG\nFlooring and Skirting (100mm-ht)\nLiving Room Dining Room Kitchen Bed Room\n\t\t\t\tVerandah Balcony Passages Lobby\nCeramic Tiles (300mm x 300mm)\nCeramic Tiles (300mm x 300mm)\nFlooring\nToilet\nAnti Skid Ceramic Tiles(300mm x300mm)\nAnti Skid Ceramic Tiles (300mm x300mm)\nWall Tiles/Dado\nKitchen 600mm height on platform\nCeramic wall tiles (300mm x 200mm)\nCeramic wall tiles (300mm x 200mm)\nToilet 2000mm height\nCeramic wall tiles (300mm x 200mm)\nCeramic wall tiles (300mm x 200mm)\nStaircase\nFloor and skirting(100mm)\nKota/marble/concrete paver/mosaic tiles\nKota/arble/concrete paver/mosaic tiles\nParking floor\nPaver Tiles\nPaver Tiles\nWall work\nExternal (200mm thick)\nRed Bricks/Conc. Hollow Blocks/Flyash Bricks\nRed Bricks/Conc. Hollow Blocks/Flyash Bricks\nInternal (150/100mm thick)\nConc. Hollow Blocks\nConc. Hollow Blocks\nExternal Plaster\n20mm thick cement Plaster in 1:4 with proper\n\t\t\t\twaterproofing\n20mm thick cement Plaster in 1:4 with proper\n\t\t\t\twaterproofing\nInternal Plaster\n12/15 mm thick cement Plaster in 1:6\n12/15 mm thick cement Plaster in 1:6\nKitchen Platform\nWidth approx 525mm\nKota Stone with Stainless Steel sink\nPolished Granite Stone with Stainless Steel sink\nWindows\n2 track Aluminium Anodised with 4mm thick glass\n3 track Aluminium Anodised with 2 track -4mm\n\t\t\t\tthick glass and and I track stainless steel mosquito mesh)\nDoors\nExternal-30mm thick Internal-25mm thick\nWooden Commercial Flush Doors\nWooden Commercial Flush Doors\nSanitary ware\nWhite Vitrified/porcelain\nWhite Vitrified/porcelain\nCP Fittings\nAs per ISI Mark\nAs per ISI Mark\nPlumbing\nPVC/uPVC/cPVC Pipes\nPVC/uPVC/cPVC Pipes\nExternal Paint\nCement Based Paint\nCement Based Paint\nInternal Paint\nOil bound distemper over a coat of Plaster of\n\t\t\t\tParis\nOil bound distemper over a coat of Plaster of\n\t\t\t\tParis\nElectrical\nElectrical work with copper wires in concealed\n\t\t\t\tPVC conduits, Provision shall be made for sufficient lighting and\n\t\t\t\tpower points. Required switches and sockets, telephone and TV\n\t\t\t\tpoints. Each bedroom shall have min 3 Nos-5 Amp points and 1No-\n\t\t\t\t15 Amp point, MCB as required\nElectrical work with copper wires in concealed\n\t\t\t\tPVC conduits, Provision shall be made for sufficient lighting and\n\t\t\t\tpower points. Required switches and sockets, telephone and TV\n\t\t\t\tpoints. Each bedroom shall have min 3 Nos-5 Amp points and 1 No-\n\t\t\t\t15 Amp point, MCB as required\nHardware Fittings\nAluminium fittings including Aldrop, tower bolt,\n\t\t\t\thandles as per ISI fittings\nAluminium fittings including Aldrop, tower bolt,\n\t\t\t\thandles as per ISI fittings\nWater Supply\nDeep Bore wells/Shallow wells/Municipal supply\n\t\t\t\tlines through Overhead tanks\nDeep Bore wells/Shallow wells/Municipal supply\n\t\t\t\tlines through Over head tanks\nSl No.\nSl No.\nComponent of Building\nComponent of Building\nRequirements\nRequirements\n3.1\nHabimhle Room\n(i) In case of one\n\t\t\t\troomed house including space for cooking\n(ii) Two roomed house\n(iii) Height in case of sloping roofs\nArea\nWidth\nHeight\nArea\nWidth\nHeight\nAvg. height\nMtn. height at eaves)\n2.5 sq.mt\n2.4 mt.\n2.6 mt.\n6.5 sq.mt\n2.1 tnt.\n2..6 mt.\n2.6 mt\n2.0 nu.\n3.2\nKitchen\n(i) Cook mg alcove\n\t\t\t\tsewing as cooking space\n(ii) Two room-d house\nArea\nWidth\nHeight\nArea\nWidth\nHeight\n2.4 sq.mt\n1.2 mt.\n2.4 mt.\n3.3 sq.mt\n1.5 mt.\n2.4 mt.\n3.3\nBathroom\nArea\nWidth\nHeight\n1.2 sq.mt\n1.0 mt.\n11 mt.\n3.4\nW.O.\nArea\nWidth\nHeight\n0.9 sq.mt\n0.9 mt.\n2.2 mt.\n3.5\nCombined bath and W.O\nArea\nWidth\nHeight\n1.2 sq_mt\n1.0 mt.\n2.2 mt.\n3.6\nBalcony\nMin. width\n0.9 m\n3.7\nStaircase\n(1) 2 storeyed -\n\t\t\t\tStraight Flight Winding\n(ii) 3 storeyed or more Strait Flight Winding\nWidth\nWidth\nMin. tread\nMax riser\nWidth\nWidth\nMin. Tread\nMax riser\n0.60 mt. (min)\n0.75 mt. (min)\n22.5 cm.\n20.0 cm.\n0.75 mt.. (min)\n0.90 int_ (min)\n25.0 cm.\n20 0 cm.\nNotes :- i) die minimum clear head room\n\t\t\t\t:bail be 2.1 rat.\nNotes :-\n3.8\nPlinth\nMin. height 30 cm from the surrounding ground\n\t\t\t\tlevel\n3.9\nLighting and Ventilation\n(a) one - tenth of\n\t\t\t\tthe room floor area for dry hot climate\n(b) one sixth of the room floor area for wet-hot\n\t\t\t\tclimate\nChapter - XII\nSavings/Repeals and Interpretation",
        "footnote": "",
        "is_definition": false,
        "sort_order": 112
    },
    "prev_section": "81",
    "next_section": "84"
}