    "act_title": "Jharkhand Building Byelaws 2016",
    "act_slug": "jharkhand-building-byelaws-2016",
    "section_label": "Section",
    "section": {
        "number": "51",
        "title": "51. Rainwater harvesting system.",
        "chapter": null,
        "content": "51.1.1 Terrace Water Collection: The terrace shall be connected to a sump or the well through a filtering tank by PVC pipe. A valve system shall be incorporated to enable the first part of the rainwater collected to be discharged out or to the soil if it is dirty. A filtering tank measuring 0.36 Sq. m. can be constructed near the sump. The tank can be divided by a perforated slab and one part should be filled by small pebbles and other by brick jali. The bottom portion of the tank should have aslope' to avoid stagnation of water.\n51.1.2 Open Ground: Where there is open ground, a portion of topsoil shall be removed and replaced with river sand to allow slow percolation of rain water. Any other method proved to be effective in conservation and harvesting of rainwater may be adopted in each and every construction taken up.",
        "footnote": "",
        "is_definition": false,
        "sort_order": 64
    },
    "prev_section": "50",
    "next_section": "52"
}