        "content": "50.6.1 Surface parking for two car spaces shall be provided near entrance for the physically handicapped persons with maximum travel distance of 30 meter from building entrance.\n50.6.2 The width of parking bay shall be minimum 3.6 meter.\n50.6.3 The information stating that the space is reserved for handicapped persons shall be conspicuously displayed.\n50.6.4 Guiding floor materials shall be provided or a device which guides visually impaired persons with audible signals or other devices which serves the same purpose shall be provided.\n50.7.1 Approach at plinth level: Every building must have at least one entrance accessible to the handicapped and shall be indicated by proper signage.\n50.7.2 Ramp Approach: Ramp shall be finished with non-slip material. Minimum width of ramp shall be 1800 mm. with maximum gradient 1:12, length of ramp shall not exceed 9 meter having 800 mm high hand rail on both sides extending 3 00mm beyond top and bottom of the ramp. Minimum gap from the adjacent wall to the hand rail shall be 50mm.\n50.7.3 Stepped Approach: For stepped approach width of tread shall not be less than 300 mm. and maximum riser shall be 150 mm. Provision of 800 mm. high hand rail on both sides of the stepped approach similar to the ramp approach shall be made.\n50.7.4 Exit/Entrance Door: Minimum clear opening of the entrance door shall be 900mm and it shall not be provided with a step that obstructs the passage of a wheel chair user. Threshold shall not be raised more than 12 mm.\n50.7.5 Entrance Landing: Entrance landing shall be provided adjacent to ramp with the minimum dimension 1800mm X 2000 mm. The entrance landing that adjoins the top end of a slope shall be provided with floor materials to attract the attention of visually impaired persons (limited to colored floor material whose color and brightness is conspicuously different from that of the surrounding floor material or the material that emits different sound to guide visually impaired persons hereinafter referred to as \"guiding floor material\"). Finishes shall have a 'non-slip surface with a texture traversable by a wheel chair. Curbs wherever provided must blend to a common level.\n50.7.6 Corridor connecting the entrance/exit for the handicapped: The corridor connecting the entrance/exit for handicapped leading directly outdoors to a place where information concerning the overall use of the specified building can be provided to visually impaired persons either by a person or by signs, shall be provided as follows:\n50.7.6.1 Guiding floor materials, shall be provided or devices that emit sound to guide visually impaired persons,\n50.7.6.2 The minimum width shall be 1250 mm.\n53.7.6.3 In case there is a difference of level, slope ways shall be provided with a slope of 1:12\n53.7.6.4 Hand rails shall be provided for ramps/slope ways at a height of 800mm.\n50.8.1 The minimum width shall be 1350 mm.\n50.8.2 Height of the riser shall not be more than 150mm and width of the tread 300mm. The steps shall not have abrupt (square) nosing.\n50.8.3 Maximum number of risers on a flight shall be limited to 12.\n50.8.4 Hand rails shall be provided on both sides and shall extend 30mm on the top and bottom of each flight of steps.\n50.9.1 A handrail not less than 600 mm. long at 1000mm. above floor level shall be fixed adjacent to the control panel.\n50.9.2 The lift lobby shall be of an inside measurement of 1800 mm x 1800mm or more.\n50.9.3 The time of an automatically closing door shall be minimum 5 seconds and the closing speed should not exceed 0.25 meter/section\n50.9.4 The interior of the cage shall be provided with a device that audibly indicates the floor the cage has reached and indicates that the door of the cage for entrance/exit is either open or closed.\n50.9.5 The control panel shall have markinu in Braille to help visually impaired.\n50.10.1 The minimum size shall be 1500 x 1750 mm.\n50.10.2 Minimum clear opening of the door shall be 900mm and the door shall swing out.\n50.10.3 Suitable arrangement of vertical/horizontal handrails with 50mm clearance from wall shall be made in the toilet.\n50.10.4 The Water Closet seat shall be 50mm from the floor.",
        "footnote": "",
        "is_definition": false,
        "sort_order": 63
    },
    "prev_section": "4",
    "next_section": "51"
}