    "act_title": "Jharkhand Building Byelaws 2016",
    "act_slug": "jharkhand-building-byelaws-2016",
    "section_label": "Section",
    "section": {
        "number": "37",
        "title": "37. Minimum setbacks for high rise buildings.",
        "chapter": null,
        "content": "Table -14: Minimum exterior open spaces around the buildings for all type of high rise buildings unless otherwise specified\nTable -14: Minimum exterior open spaces around the buildings for all type of high rise buildings unless otherwise specified\nSl.\nSl.\nHeight of the Building Upto (m)\nHeight of the Building Upto (m)\nExterior open spaces to be left out on all\n\t\t\t\tsides in m.\nExterior open spaces to be left out on all\n\t\t\t\tsides in m.\nFront setback\nFront setback\nSide and Rear setback\nSide and Rear setback\n1\nMore than 16.4 and upto 19.25m\n6.5\n4.5\n2\nMore than 19.25m and upto 23.10m\n7.5\n4.5\n3\nMore than 23.10m and upto 30m\n8.0\n5.0\n4\nIn case of buildings of more than 30m height, for\n\t\t\t\tevery increase in height of 3.35m. or fraction thereof or\n\t\t\t\taddition of one floor, 1m. in the front set back and 0.75 m. in\n\t\t\t\tthe sides and rear setbacks shall be added.\nNote:- (1) In no case the minimum setbacks shall be less than those specified in sub-section 42.1 of these Bye Law for high rise buildings in the mentioned category.\n(2) In case of multi storied buildings the exterior open space around a building shall be of hard surface capable of taking load of fire, engine weighting up to 45 tones.\nCoverage of Building\nMaximum ground coverage",
        "footnote": "",
        "is_definition": false,
        "sort_order": 38
    },
    "prev_section": "36",
    "next_section": "1"
}