    "act_title": "Faridabad Complex Administration Building Rules, 1989",
    "act_slug": "faridabad-complex-administration-building-rules-1989",
    "section_label": "Section",
    "section": {
        "number": "5",
        "title": "5. Building Plan. Sections 43(2), 57(2)(m).",
        "chapter": null,
        "content": "(i) 1:50 for plots up to 1000 square metres in size.\n(ii) 1:100 for plots over 1000 square metres.\n(i) the plans of all the floors, all external elevations and sections (longitudinal and cross) illustrating distinctly all the different levels through floor, staircase, W.C. bath, kitchen and garage;\n(ii) the plinth level of the building with reference to the level of the centre of the street or streets on which the proposed building is to abut;\n(iii) the schedule indicating the sizes of the doors, windows, opening and other methods of ventilation of each room;\n(iv) the means of access to the building and its various floors together with the means of escape in case of fire if required under the specific rules;\n(v) in the case of proposed additions and alterations to an existing building new works on the plan by indelible distinctive colours with a key to the colours used; and",
        "footnote": "",
        "is_definition": false,
        "sort_order": 4
    },
    "prev_section": "43",
    "next_section": "6"
}