    "act_title": "Faridabad Complex Administration Building Rules, 1989",
    "act_slug": "faridabad-complex-administration-building-rules-1989",
    "section_label": "Section",
    "section": {
        "number": "46",
        "title": "46. Slenderness ratio. Sections 43(2), 57(2)(m).",
        "chapter": null,
        "content": "Slenderness Ratio\nReduction in maximum permissible pressure due to\n\t\t\t\t\tslenderness ratio exceeding six\n7\n10 %\n8\n20 %\n9\n30 %\n10\n40 %\n11\n50 %\n12\n60 %\n(i) for walls with no lateral support at top\n1½ actual storey height\n(ii) for walls with no lateral support at top\n¾ actual storey height\n(iii) piers with no lateral support at top\n2 actual storey height\n(iv) Piers with lateral support at top\nActual storey height",
        "footnote": "",
        "is_definition": false,
        "sort_order": 44
    },
    "prev_section": "45",
    "next_section": "47"
}