        "title": "40. Commercial building.",
        "chapter": null,
        "content": "Height, Coverage, Far etc. for Commercial Buildings\nHeight, Coverage, Far etc. for Commercial Buildings\nTable-5\nTable-5\nArea of the plot in Sq. mtrs.\nMaximum % of Coverage\nFloor area ratio\nMinimum Road width in mtrs\nMinimum Front open space in mtrs.\nUpto 100\n75\n1.5\n6\n1.5\n101 to 200\n70\n1.5\n9\n1.5\n201 to 300\n70\n1.75\n12\n1.5\n301 to 400\n65\n1.75\n12\n2.0\n401 to 500\n55\n2.0\n18\n2.0\n501 to 1000\n50\n2.0\n18\n3.0\n1001 to 2001\n50\n2.0\n24\n4.0\n2001 & above\n50\n2.0\n30\n5.0 and above\nSide and Rear Open Spaces (Setbacks) for Commercial Buildings\nSide and Rear Open Spaces (Setbacks) for Commercial Buildings\nTable-6\nTable-6\nArea of Plot in square meters\nMinimum Right side open space in meters\nMinimum Left side open space in meters\nMinimum rear side open space in meters\nUpto 100\nNil\nNil\nNil\n101 to 200\n1.0\n1.0\n1.5\n201 to 500\n2.0\n2.0\n2.5\n501 to 1000\n2.0\n2.0\n3.0\nAbove 1000\n3.0\n3.0\n3.5",
        "footnote": "",
        "is_definition": false,
        "sort_order": 39
    },
    "prev_section": "39",
    "next_section": "41"
}