    "act_title": "Andhra Pradesh Revised Building Rules, 2008",
    "act_slug": "andhra-pradesh-revised-building-rules-2008",
    "section_label": "Section",
    "section": {
        "number": "9",
        "title": "9. Requirements for High Rise Buildings.",
        "chapter": null,
        "content": "Prior Clearance From Fire Dept, and Airport Authority:\nTABLE IV\nTABLE IV\nHeight of building\nHeight of building\nMinimum abutting road width required (in\n\t\t\t\tmetres)\nMinimum abutting road width required (in\n\t\t\t\tmetres)\nMinimum road open space on remaining sides (in\n\t\t\t\tmetres)*\nMinimum road open space on remaining sides (in\n\t\t\t\tmetres)*\n(1)\n(1)\n(2)\n(2)\n(3)\n(3)\nUp to 21 mt.\n12.2\n7\nAbove 21 mt. & up to 24mt.\n12.2\n8\nAbove 24 m & up to 27m\n18\n9\nAbove 27 m & up to 30m\n18\n10\nAbove 30 m & up to 35m\n24\n11\nAbove 35 m & up to 40m\n24\n12\n•   For heights above 40 m, specific approval from the Government shall be required;\n•   The front open space shall be on the basis on the abutting road width and shall be either as given in shall be either as given in Col. 3 of above Table IV or the Building line given Table III whichever is more;\n(i) The abutting road has to be black-topped with minimum 2-lane carriageway. Service roads where required as per these Rules, shall be minimum 7 m wide with minimum 2-lane black toped carriageway.\n(ii) For upper floors from 2nd floor onwards, balcony projection of up to 2 m may be allowed projecting onto the open spaces.\n(iii) The open space to be left between two blocks shall be equivalent to the open space mentioned in Column (3) of above Table IV.\n(iv) It is permitted to transfer up to two metres of setback from one side to the other side, which needs to be uniform at any given point, subject to maintaining of minimum setback of 7 m on all sides.\n(v) where the lighting and ventilation of a building is through the means of a chowk or inner courtyard or interior open space/duct, such open space shall be open to sky and of area at least 25 sq.m. and no side shall be less than 3 m.\nTower And Podium Type High Rise Structure May Be Allowed With The Following:\n(a) For podium, i.e. Ground plus first floor; alround setbacks shall be 7 m alround.\n(b) For the Tower block: The maximum permissible coverage and minimum alround setbacks shall be 50% of the Podium Block, and shall be at least 3m from the Podium edge.\n(c) The fire safety and fire escape measures for the Tower Block shall be independent of the Podium Block.\n(a) At ground level\n:\nMinimum 9 metres alround open space for the\n\t\t\t\tfirst five floors\n(b) At upper floors\n:\nincrease of 1 metre alround open space or more,\n\t\t\t\tfor every 5 upper floors of 15 m height or part thereof, over and\n\t\t\t\tabove the ground level open space of minimum 9 metres.\nProvision of greenery.\n(b) In addition to the above, a minimum 2 metres wide green planting strip in the periphery on all sides within the setbacks are required to be developed and maintained with greenery and trees in all high rise building sites.\n(c) Rain water harvesting structures shall be provided in the prescribed manner within the setbacks.\nCompliance of National Building Code Provisions for Amenities and Facilities in All High Rise Buildings.\n(ii) Such buildings shall be undertaken by owners by engaging registered architect, licensed builders/ developers and licensed structural engineers. The designs and building plans shall be countersigned by the owner, licensed developer, registered architect, licensed engineer and a qualified and licensed structural engineer who shall be responsible for the supervision, and structural safety of the high-rise building and ensuring that such buildings are designed for compliance with earth quake resistance and resisting other natural hazards, and a fire engineer/fire consultant who shall be responsible fire and life safety and specifications compliance in such buildings. The Completion Certificate shall clearly mentioned that the norms for the above structural safety and fire and life safety requirements have been followed in the design and construction of buildings for making the buildings resistant to earthquake, compliance with structural safety and fire safety requirements.\n(iii) The work of the building services like sanitation, plumbing, fire and life safety requirements, lifts, electrical installations, and other utility services shall be executed under the planning, design and supervision of qualified and competent technical personnel.\n(iv) In addition to the required staircases and lifts, there shall be at least one fire escape staircase and lift. These lifts shall be got certified from the manufacturer's authorized Service technical personnel from time to time.\n(v) Provision for power generator shall be made in such buildings.\n(vi) Such buildings shall be planned, designed and constructed to ensure fire and safety requirements are met and maintained and shall comply in accordance with the Fire Protection Requirements of National Building Code of India.\n(vii) The facilities for providing fire protection and fire fighting facilities in such buildings shall be in compliance with the stipulations laid down and clearance issued by the Fire Department from time to time. NOC from the Fire Department shall be obtained from time to time regarding the fire safety requirements and facilities installed. The designs and installations regarding fire protection and safety measures including exit requirements and smoke containment and smoke management measures shall be undertaken through a fire engineer/fire consultant.\n(viii) Compliance of the parking requirements shall be as given in these rules. The parking facilities and vehicles driveways etc. shall be maintained to the satisfaction of the sanctioning Authority.\n(ix) Such buildings shall be provided with solar water heating system in the building and solar lighting in the site for outdoor lighting, etc. and give a bank guarantee to this effect to the sanctioning authority for compliance of the same.\n(x) All High-Rise buildings with covered area above 300 sq.m. shall be designed and constructed to provide facilities to the physically handicapped persons as prescribed in the National Building Code of India, 2005.\n(xi) In all buildings irrespective of above height provisions, the requirements of parts of the building like size and area requirements of habitable rooms, kitchen, bathrooms and Water closets, other areas, corridor and staircase widths, service ducts, etc. shall conform to the provisions of the National Building Code of India, 2005.\n(xii) All environmental aspects like provision of Rain water harvesting structures, greenery, solar heating and lighting systems and provisions of the Andhra Pradesh Water, Land and Trees Act 2002 shall be complied in such of the sites and Schemes where these are applicable.",
        "footnote": "",
        "is_definition": false,
        "sort_order": 8
    },
    "prev_section": "8",
    "next_section": "10"
}