    "act_title": "Andhra Pradesh Building Rules - 2012",
    "act_slug": "andhra-pradesh-building-rules-2012",
    "section_label": "Section",
    "section": {
        "number": "12",
        "title": "12. Buildings With Central Courtyard For Commercial Use.",
        "chapter": null,
        "content": "(b) The Front setback shall be as per Table-III of rule-5 & Table-IV of rule-7 for Non High Rise & High Rise buildings respectively.\n(c) The minimum open space / setback on sides and rear except front, shall be\n(i) 2m for building height up to 15m;\n(ii) 3m for building height up to 18m;\n(iii) 7m in case of high rise buildings up to 30m height and buildings coming under purview of Andhra Pradesh Fire Services Act-1999.\n(d) The area so saved is transferred to the central area / space or court yard;\n(e) The depth of such courtyard shall be at least 50% of the average building depth and the minimum width shall be 10m.",
        "footnote": "",
        "is_definition": false,
        "sort_order": 11
    },
    "prev_section": "11",
    "next_section": "13"
}